OWNER’S MANUALJ-300™ Series J - 315J - 325J - 335J - 345 J - 355 J - 365 J - 3752530-398U Rev. C
6J-300 Series3.1 Entrapment RiskThe Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) t
7J-300 SeriesJ-300 Series3. ! DANGER: RISK OF SEVERE INJURY OR DROWNING! Body entrapment: May occur when part of the torso becomes entrapped, insert
8J-300 Series3.3 Important Additional CSA Safety Instructions (Canada Only)When using this electrical equipment, basic safety precautions should alwa
9J-300 SeriesJ-300 Series4.0 Choosing A LocationIMPORTANT: Because of the combined weight of the spa, water and users, it is extremely important tha
10J-300 Series4.1 Outdoor LocationIn selecting the ideal outdoor location for your spa, we suggest that you take into consideration:The proximity to
11J-300 SeriesJ-300 Series In the unlikely event that you should ever need to access or gain entry to any portion of the spa for
12J-300 Series5.0 General Electrical Safety InstructionsYour new Jacuzzi® spa is equipped with a “state-of-the-art” equipment system. It contains th
13J-300 SeriesJ-300 Series240V/40A* 240V/50A** 240V/60A***Circuit Breaker (2-Pole):
14J-300 Series230V/20A* 230V/30A** 230V/40A***Circuit Breaker: 20A 30A 40ANumber of Wires: 3
15J-300 SeriesJ-300 Series7.0 Electrical Wiring InstructionsIMPORTANT NOTICE: The electrical wiring of this spa must meet the requirements of the Na
Attention New Spa Owner!Congratulations on the purchase of your new Jacuzzi® spa! The following is a list of automated functions performed by your spa
16J-300 SeriesANSI/NFPA 70. The disconnecting means must be readily accessible to the spa’s occupant but installed at least 5 feet (1.5m) from spa wat
17J-300 SeriesJ-300 SeriesFigure B Control BoxTB13211. Terminal Block2. Bonding Lug3. Grounding TerminalGRNWHTWHTBLKBLKBLKRED123Figure-CTB1to Circu
18J-300 Series8.0 Spa Fill Up ProcedureFor best results, read each step in its entirety before proceeding with that step.Prepare The Spa For Filling1
19J-300 SeriesJ-300 SeriesWARNING: RISK OF POISONING OR DEATH.Never leave chemicals opened and accessible to anyone. Use chemicals according to the v
20J-300 SeriesPlace Cover On Spa8. Keeping the insulating cover in place anytime the spa is not in • use will reduce the time required for heating, th
21J-300 SeriesJ-300 Series10. Leave spa cover open during this step to allow excessive chemical vapors to exit spa, protecting pillows and plastic k
22J-300 SeriesWARNING: RISK OF PERSONAL INJURY.To decrease the risk of injury, entrapment or drowning, • never leave your hot tub unattended for any r
23J-300 SeriesJ-300 Series9.0 Control Functions9.1 Control PanelA. LED Display: Can display current water temperature (default display), water tem
24J-300 Series9.2 General Spa Features And Controls17811222225534613 131313151451010101218181896161717171716Control Panel1. Toggle Air Controls2. Fil
25J-300 SeriesJ-300 Series10.0 Operating InstructionsThe spa control system has automatic functions that operate upon start-up and normal operation t
Table of Contents1.0 Important Spa Owner Information...12.0 FCC Notice ...
26J-300 Series10.4 Light Mode ButtonThis button offers 4 light modes for your enjoyment. Press this button to select your favorite lighting effect a
27J-300 SeriesJ-300 Series10.7 Selecting Desired Massage ActionAll models incorporate a massage selector valve that allows you to customize the mass
28J-300 Series11.0 Automatic Filtration CyclesYour new spa includes a 24-hour circulation pump which lters the water continuously. The circulation p
29J-300 SeriesJ-300 SeriesF0 5 minutes of ltration per day (one 5 minute “Blow-Out” cycle every 24 hours to purge a
30J-300 Series12.0 Spa MaintenanceProper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Jacuzzi
31J-300 SeriesJ-300 SeriesAn optional chemical feeder is available through your authorized Jacuzzi dealer that installs under the lter cap (#2472-67
32J-300 SeriesELift unthreaded lter cartridge from skimmer well.FIf used, remove the chemical feeder as instructed prior to rinsing the lter cartrid
33J-300 SeriesJ-300 SeriesPeriodically, the lter cartridge will need a more thorough cleaning to remove imbedded oils and minerals. For this, we sugg
34J-300 Series12.3 Pillow CareRemove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. To maintain water
35J-300 SeriesJ-300 SeriesCAUTION: Never spray cabinet with a garden hose for any reason since this action may induce an electrical short in the spa’
12.0 Spa Maintenance ...3012.1 Cleaning The Filters...
36J-300 Seriesthe equipment. We recommend you consult your authorized Jacuzzi dealer for guidance before attempting to restart your spa under these co
37J-300 SeriesJ-300 Series13.2 SanitizingTo destroy bacteria and organic compounds in the spa water, a sanitizer must be used regularly. Chlorine and
38J-300 Series Your spa has a self-diagnostic control system. The system will automatically display the following
39J-300 SeriesJ-300 Series14.6 Panel Flashes FL1 or FL2A ashing “FL1” display means the ow switch is malfunctioning open, the lter cartridge is
40J-300 Series In the event your Jacuzzi spa is not working the way it should, please rst review all the installation
41J-300 SeriesJ-300 Series15.5 No Heat1. Check thermostat setting.2. Keep the spa cover in place while heating.3. Check the settings to see if you
42J-300 Series16.0 Circuit Board Diagrams Dedicated Power Models (60 Hz)This wiring diagram
43J-300 SeriesJ-300 Series (60 Hz)This wiring diagram is used for all North American 120
44J-300 Series This wiring diagram is used for all Export 230 VAC 50 Hz spa models.Opti
45J-300 SeriesJ-300 Series16.4 Export J-315 and J-325 Models (50 Hz)This wiring diagram is used for all Export 230 VAC 50 Hz spa models.OzonatorOptio
1J-300 SeriesJ-300 Series1.0 Important Spa Owner InformationYour Jacuzzi® J-300 Series spa is constructed to the highest standards and is capable of
46J-300 Series17.0 Optional Stereo Receiver Functions18 9 10 11 12 13 14 15 16 172 3 4 5 6 7J-335/J-345/J-355/J-365/J-375 Models Only:To start enjoyi
47J-300 SeriesJ-300 SeriesDISP Button:6. Press DISP to switch between clock and station frequency. When selected, the clock will display for 5 seco
48J-300 Series18 9 10 11 12 13 14 15 16 172 3 4 5 6 713. In tuner mode, any station can be stored as preset 4 by simply pressin
49J-300 SeriesJ-300 SeriesEject Button (Not Illustrated):19. To eject CD, press OPEN and ip-down the front access panel, then press the Eject butt
50J-300 Seriesbeen recorded on an MP3 disc, NO FOLD, NO TRK, NO TLT, NO ALBM, NO ART will display.24. A directory that
51J-300 SeriesJ-300 Series26. Marine Grade AM/FM/CD/CD-R/CD-RW/MP-3• 7 Bands of Weather Band• Stainless Steel Sea
52J-300 SeriesExample of a disc's folder/file hierarchyFolderFileLevel 1 Level 2 Level 3 Level 4 Level 5Operation of the keysPress (Track Do
53J-300 SeriesJ-300 Series17.1 Audio System Remote Control FunctionsA remote control is supplied on all spas with the optional stereo system. This re
54J-300 Series17.2 External MP3 Player ConnectionConnecting An External MP3 Player (Purchased Separately)Any battery powered MP3 player can be connec
55J-300 SeriesJ-300 Series17.3 Wireless Remote Battery Replacement Procedure1. Turn the remote unit over and locate the battery door (Figure A).2.
2J-300 Series3.0 Important Safety Instructions for all Spa OwnersREAD AND FOLLOW ALL INSTRUCTIONS CAREFULLY!This spa was manufactured to meet the sta
56J-300 Series56
3J-300 SeriesJ-300 Serieson the grounding lug, inside the equipment compartment on the equipment box. A grounding wire connector is provided on this u
4J-300 Series6. ! WARNING: RISK OF SEVERE INJURY OR DEATH! Since excessive water temperatures have a high potential for causing • fetal damage during
5J-300 SeriesJ-300 Series9. CAUTION: TO DECREASE RISK OF PRODUCT DAMAGE.Maintain water chemistry in accordance with manufacturer’s • instructions.Pr
Commenti su questo manuale